Ambient temperature: 
  • Standard: -20 to +70 °C
  • Flameproof/dust ignition proof: -20 to +60 °C
  • Low temperature: -60 to +60 °C
Cable entries: 
  • Standard: 2 x PF3/4″
  • Flameproof/dust ignition proof: 2 x NPT3/4″ or 2 X M25
Limit switches:
  • HL-05KN, HL-07KN: 2 x SPDT (16 A 250 V ac) 
  • HL-10KN to HL-25KN: 4 x SPDT (16 A 250 V ac)

Force switches: 2 x SPDT (16 A 250 V ac)

Space heater: HL-05KN, 07KN: 5 W  / HL-10KN to 25KN: 10 W

Control options: 
  • PIU: Potentiometer unit (0-1 kΩ) • CPT: Current Position Transmitter (output: 4-20 mA dc)
  • PCU: Proportional Control Unit (intput/output: 0-10 V dc or 4-20 mA dc)
  • PROFIBUS DP interface modules
  • MODBUS modules
Local control option: 
  • LCU-B: LED local control unit (integral switch)
  • LCU-C: LCD local control unit (integral switch, auto phase discriminator, separate terminal box)
  • RBP: Rechargeable Battery Pack for emergency fail safe operation

HL Series (Linear)

The HL Series, electric linear actuator, is designed for linear valve applications such as globe valve.

  • Precise modulating control (300:1 at maximum stroke) as an option.
  • Flameproof (Ex db IIB T4) and dust ignition proof (Ex tb IIIC T135°C) enclosures as an option
  • Communication (PROFIBUS, MODBUS) options

Material: Aluminium alloy

Enclosure: 
  • Standard: weatherproof IP67
  • Flameproof: Ex db IIB T4
  • Dust ignition proof: Ex tb IIIC T135°C
  • Output force: 5,000 to 25,000 N
Power: 
  • 110/220 V ac 1ph, 50/60 Hz, ±10%
  • 220/380/440/480 V ac 3ph, 50/60 Hz, ±10%
  • 24 V dc 
  • 24 V ac/dc
  • Duty cycle: 
  • S2 (on-off): 30 mins (room temp., average load of 50% of max. torque) 
  • S4 (modulating): 40~70% 800~1200 starts/hour (room temp., average load of 50% of max. torque)
Duty cycle:
  • S2 (on-off): 30 mins (room temp., average load of 50% of max. torque)
  • S4 (modulating): 40~70% 800~1200 starts/hour (room temp., average load of 50% of max. torque)

View datasheet for complete information