Travel angle: 
  • Standard: 0-90° 
  • Extension: 0-120°, 135°, 180°, 270°, etc.
Operating time (90°): 
  • 14 s (50 Hz), 12 s (60 Hz),
  • 12 s (24 V dc & 24 V ac/dc)
    • Operating time varies depending on the torque used.
Ambient temperature: 
  • Standard: -20 to +70 °C
  • Flameproof: -20 to +60 °C
Cable entries: 
  • Standard: 2 x PG13.5, 2 x PF1/2″, 2 x NPT1/2″, 2 x M20 
  • Flameproof: 2 x NPT1/2″, 2 x M25

Limit switches: 4 x SPDT (5 A 250 V ac)

Flange (ISO 5211): 
  • Standard: F03, F05, F07 (14 mm Star)
  • Flameproof: F04, F05, F07 (14 mm Star)
Weight: 
  • Standard: 3.0 kg
  • Flameproof: 4.2 kg
  • Proportional Control Unit(modulating): 4.5 kg
Control options: 
  • PIU: Potentiometer unit (0-1 kΩ) 
  • CPT: Current Position Transmitter (output: 4-20 mA dc)
  • PCU: Proportional Control Unit (intput/output: 0-10 V dc or 4-20 mA dc)
  • MODBUS modules
Local control option: 
  • LCU-D: Local control unit
  • LCU-Z: LED local control unit

HQ-006 (Quarter-turn)

The HQ-006, electric part-turn actuator, is designed for small size rotary valve applications, such as buttery, ball, and plug valve.

• Aluminum die-cast, compact size, and light weight.
• Reversible motor with high torque and low current.
• Manual lever.
• Flameproof (Ex db IIB T4) option.
• Proportional Control Unit (PCU, modulating) and Local Control Unit (LCU) options.
• MODBUS communication option.

Material: Aluminium alloy

Enclosure: 
  • Standard: weatherproof enclosure IP67 
  • Watertight enclosure: IP68 (10 m, 72 hours)
  • Flameproof enclosure: Ex db IIB T4

Torque: 60 Nm

Power: 
  • 110/220 V ac 1ph, 50/60 Hz, ±10%
  • 24 V dc
  • 24 V ac/dc
Duty cycle:
  • S2 (on-off): 30 mins (room temp., average load of 50% of max. torque)
  • S4 (modulating): 40% 800-1200 starts/hour (room temp., average load of 50% of max. torque)

View datasheet for complete information