Travel angle:
- Standard: 0-90°
- Extension: 0-120°, 135°, 180°, 270°, etc.
Operating time (90°):
- 14 s (50 Hz), 12 s (60 Hz),
- 12 s (24 V dc & 24 V ac/dc)
- Operating time varies depending on the torque used.
Ambient temperature:
- Standard: -20 to +70 °C
- Flameproof: -20 to +60 °C
Cable entries:
- Standard: 2 x PG13.5, 2 x PF1/2″, 2 x NPT1/2″, 2 x M20
- Flameproof: 2 x NPT1/2″, 2 x M25
Limit switches: 4 x SPDT (5 A 250 V ac)
Flange (ISO 5211):
- Standard: F03, F05, F07 (14 mm Star)
- Flameproof: F04, F05, F07 (14 mm Star)
Weight:
- Standard: 3.0 kg
- Flameproof: 4.2 kg
- Proportional Control Unit(modulating): 4.5 kg
Control options:
- PIU: Potentiometer unit (0-1 kΩ)
- CPT: Current Position Transmitter (output: 4-20 mA dc)
- PCU: Proportional Control Unit (intput/output: 0-10 V dc or 4-20 mA dc)
- MODBUS modules
Local control option:
- LCU-D: Local control unit
- LCU-Z: LED local control unit
HQ-006 (Quarter-turn)
The HQ-006, electric part-turn actuator, is designed for small size rotary valve applications, such as buttery, ball, and plug valve.
• Aluminum die-cast, compact size, and light weight.
• Reversible motor with high torque and low current.
• Manual lever.
• Flameproof (Ex db IIB T4) option.
• Proportional Control Unit (PCU, modulating) and Local Control Unit (LCU) options.
• MODBUS communication option.
Material: Aluminium alloy
Enclosure:
- Standard: weatherproof enclosure IP67
- Watertight enclosure: IP68 (10 m, 72 hours)
- Flameproof enclosure: Ex db IIB T4
Torque: 60 Nm
Power:
- 110/220 V ac 1ph, 50/60 Hz, ±10%
- 24 V dc
- 24 V ac/dc
Duty cycle:
- S2 (on-off): 30 mins (room temp., average load of 50% of max. torque)
- S4 (modulating): 40% 800-1200 starts/hour (room temp., average load of 50% of max. torque)