Ambient temperature: 
  • Standard: -20 to +70 °C
  • Flameproof/dust ignition proof: -20 to +60 °C 
  • Low temperature: -60 to +60 °C (EAC)
Cable entries: 
  • Standard: 2 x PF3/4″ (HQ-008 to HQ-300), 2 x PF3/4″ + PF 1″ (HQ-350 to HQ-900) 
  • Flameproof/dust ignition proof: 2 x NPT3/4″ or 2 X M25
  • Limit switches: 
  • Standard: 2 x SPDT (16 A 250 V ac) (HQ-008, 010), 4 x SPDT (16 A 250 V ac) (HQ-015 to 900) 
  • Additional Limit Switches(ALS): +2 x SPDT
Torque switches: 
  • Standard: 2 x SPDT (16 A 250 V ac) (except HQ-008,010)
  • Additional Torque Switches(ATS): +2 x SPDT (except HQ-008, 010)
Space heater: 
  • HQ-008, 010: 5 W 
  • HQ-015 to HQ-900: 10 W
Control options: PIU:
  • Potentiometer unit (0-1 kΩ)
  • CPT: Current Position Transmitter (output: 4-20 mA dc) 
  • PCU: Proportional Control Unit (intput/output: 0-10 V dc or 4-20 mA dc)
  • PROFIBUS DP interface modules
  • MODBUS modules 
  • CANopen modules
Local control option:
  • LCU-Z: LED local control unit 
  • LCU-B: LED local control unit (integral switch) 
  • LCU-C: LCD local control unit (integral switch, auto phase discriminator, separate terminal box) 
  • RBP: Rechargeable Battery Pack for emergency fail safe operation
  • LCU-B(EX): Explosion proof LED local control unit (integral switch, Ex db IIB T4, Ex tb IIIC T135°C Db) 
  • LCU-2B(EX): Explosion proof LED local control unit (integral switch, separate terminal box, Ex db IIB T4, Ex tb IIIC T135°C Db)
  • LCU-C(EX) and more

HQ Series (Quarter-turn)

The HQ Series, electric part-turn actuator, is designed for rotary valve applications such as ball, butterfly, and plug valves.

  • Listed as a World Class Korea product since 2013 with a high global market share.
  • Variety of options are available.
  • Lightweight, robust, and has high corrosion protection.
  • Precise modulating control (250:1) as an option.
  • Maximum output torque up to 3,000 Nm with 24 V dc.
  • Flameproof (Ex db IIB T4) and dust ignition proof (Ex tb IIIC T135°C) enclosures as an option.
  • IP68 (upto 10 m, 72 hours) as an option.
  •  Communication (PROFIBUS, MODBUS, CANOpen) options.

Material: Aluminium alloy and nodular cast iron

Enclosure: 
  • Standard: weatherproof enclosure IP67, NEMA 4, 4X, 6
  • Watertight enclosure: IP68 (10 m, 72 hours)
  • Flameproof enclosure: Ex db IIB T4
  • Dust ignition proof enclosure: Ex tb IIIC T135°C

Torque:  80~9,000 Nm

Power: 
  • 110/220 V ac 1ph, 50/60 Hz, ±10%
  • 220/380/440/480 V ac 3ph, 50/60 Hz, ±10%
  • 12 V dc (HQ-008, 010)
  • 24 V dc (HQ-008 to HQ-300) 
  • 24 V ac/dc (HQ-008 to HQ-300)
Duty cycle: 
  • S2 (on-off): 30 mins 
  • S4 (modulating): 70% 800-1200 starts/hour (room temp., average load of 50% of max. torque)
Travel angle: 
  • Standard: 0~90° 
  • Extension: 0~120°, 135°, 180°, 270°, etc.